Ara290 Peptide Raw Powder >99% HPLC Verified
Purity ≥ 99%
research peptides
COA Certificate
HPLC Purity Test
MS Mass Spec
Purity
≥ 99.0%
Standard
USP / EP
Delivery
7-15 Days
MOQ
Negotiable
  • Solid-phase synthesis, impurity ≤ 0.1%
  • GMP-compliant manufacturing workshops
  • Full QC: COA, HPLC, MS documentation
  • Bulk & custom synthesis supported
  • OEM / ODM export solutions available
  • Ships to 30+ countries worldwide
research peptides

Ara290 Peptide Raw Powder >99% HPLC Verified

Ara290 Peptide, >99% by HPLC with UV Detection, Lyophilized Powder — supplied as a research-grade raw material with batch-specific Certificate of Analysis naming each analytical method used.

  • Mass spectrometry confirms identity per batch, aligning with receiving laboratory QC protocols
  • Retained samples enable repeat testing if re-verification is required
  • Full analytical method documentation provided so your team can replicate purity assessment independently
  • Temperature-controlled dispatch with transit records maintains -20°C cold chain integrity
  • Production capacity supports both trial-scale and bulk research quantities from the same verified source
Quality Guaranteed
Ships to 30+ Countries
Fast 7-15 Day Delivery
GMP Workshop

Product Details

Verified Analytical Methods — Every shipment of Ara290 raw material includes a batch-specific certificate naming the exact HPLC conditions and MS parameters used to establish purity and identity.

Product Specification

Parameter Value
Product Type Peptide Raw Material
Sequence Ara290
Appearance Lyophilized Powder
Purity >99% by HPLC with UV detection
Identity Confirmation Mass Spectrometry (MS)
Packaging Options 5mg, 10mg, 15mg, 20mg, 30mg per bottle
Container Type Bottle / Box
Storage Temperature -20°C, sealed, light-protected
Reconstitution Solvent Sterile water or buffer to 1–10 mg/mL
Reconstituted Stability ~1 month at 4°C, ~6 months at -20°C
Shelf Life (Lyophilized) 24 months from manufacturing date at -20°C
Freeze-Thaw Limit Aliquot to avoid repeated freeze-thaw cycles
Production Capacity 10,000 g/year
HS Code 29371290
Quality Standards GMP, ISO 9001
Origin China

Intended Use

Use Category Notes
Laboratory research input Supplied as lyophilized powder for in vitro analytical workflows
In vitro cellular signaling pathway investigation Compatible with cell culture media preparation at research scale
Receptor interaction studies Identity verified by MS for binding assay reference use
Protein binding assays HPLC-verified purity supports reproducible assay conditions
Cell culture studies Reconstituted with sterile water or buffer per documented protocol

Supplied as a raw material for research and manufacturing use. Not for human or veterinary use. Not a finished product.

Why Method Transparency Changes the Purity Number You See

Ara290 peptide purity HPLC analytical verification depends entirely on the chromatographic conditions stated on the certificate.

In analytical laboratories, the same lyophilized peptide powder can return different purity figures when tested on different columns or under different gradient programs. A 0.8% discrepancy between supplier and buyer labs is not unusual when one party uses a C18 column and the other uses a phenyl-hexyl phase, or when UV detection wavelengths are set apart. Every batch of Ara290 shipped from this facility carries a certificate that names the specific column chemistry, mobile phase composition, flow rate, and detection wavelength. [NEED_CITE: HPLC method validation requirements per ICH guidelines] This alignment step removes guesswork when the receiving QC team runs their own verification.

Ara290 lyophilized peptide raw powder in sealed glass bottle with batch-specific COA

Chromatographic Conditions Written on Every Certificate

The stated >99% purity for Ara290 is determined by HPLC with UV detection, and the complete method parameters accompany each shipment. The certificate of analysis specifies the column type, gradient profile, injection volume, and wavelength so that the receiving laboratory can replicate the separation. This level of Ara290 peptide purity HPLC analytical verification means your QC manager does not need to reverse-engineer the supplier’s method before confirming the batch.

Mass Spectrometry Confirms the Sequence Before Release

Identity verification by mass spectrometry is performed on every production lot. The MS spectrum is recorded and attached to the batch documentation, providing a direct molecular weight readout that confirms the synthesized sequence matches the target. When the receiving lab observes an unexpected peak during their own HPLC run, the MS data offers a second analytical dimension to investigate whether the discrepancy originates from the peptide itself or from the chromatographic setup. [NEED_CITE: mass spectrometry confirmation standards for synthetic peptides]

Specification Parameters and Their Downstream Impact

The lyophilized state of Ara290 directly affects how the material behaves once it arrives at the receiving bench. Lyophilization removes bulk water, slowing hydrolytic degradation pathways and supporting the documented 24-month shelf life at -20°C. However, each freeze-thaw cycle of a reconstituted solution introduces the risk of aggregation and surface adsorption, which is why the handling sheet recommends aliquoting into single-use volumes immediately after reconstitution at 1–10 mg/mL. The stated >99% purity by HPLC with UV detection reflects the peptide-related substance profile at the time of release; impurities such as deletion sequences or oxidation by-products, if present below the reporting threshold, can still interfere with sensitive receptor binding assays if the receiving lab uses a detection method with a lower limit of quantitation. Aligning the detection wavelength between supplier and buyer ensures that the impurity profile is evaluated on a consistent basis. Storage at -20°C in a sealed, light-protected container prevents photo-induced modifications that could shift the chromatographic profile during long-term storage.

Temperature-controlled cold chain packaging with transit data logger for Ara290 peptide shipment

The Cost of Receiving a Certificate Without Context

When a certificate of analysis omits the analytical method, the receiving laboratory has no baseline to calibrate their own verification. Discrepancies then escalate into multi-week exchanges of emails, repeat shipments, and in some cases full batch rejection. [NEED_CITE: common causes of certificate-of-analysis disputes in peptide procurement] Method-level documentation eliminates this friction. A COA that specifies column dimensions, gradient timing, and detection parameters lets the QC team reproduce the separation within one working shift rather than spending days optimizing conditions blindly.

Analytical Documentation Built for Verification Workflows

Every order of Ara290 is backed by a documentation set designed for laboratories that will re-test the material upon receipt. The batch-specific certificate of analysis states the exact HPLC conditions used, the MS confirmation result, and the release specification that the batch met. Retained samples from each production lot are held on file so that if a discrepancy arises weeks after delivery, the original material is available for parallel re-testing under both the supplier’s and the buyer’s methods. This traceability structure shortens dispute resolution from weeks to days. Analytical method summaries are provided in a format that allows the buyer’s QC team to input the parameters directly into their own instrument software. Complete shipping records include cold-chain transit logs with temperature data captured throughout the journey.

Inquiry Preparation for Receiving Laboratories

When requesting a quotation or sample, include the analytical method your laboratory uses for purity verification so that method alignment can be confirmed before dispatch. Specify the packaging size required from the available range (5mg through 30mg) and whether retained sample storage is needed for future reference. If your import jurisdiction requires specific origin or safety documentation, list the required forms at the inquiry stage to ensure the documentation package is complete before the shipment leaves the facility.

Frequently Asked Questions

Q: How is Ara290 peptide purity verified and which analytical method is used?
A: Purity is determined by HPLC with UV detection, and the complete chromatographic conditions — column type, mobile phase, gradient, wavelength — are stated on the batch-specific certificate of analysis. Mass spectrometry provides a second verification layer confirming the molecular identity of each lot before release.

Q: How does the batch-specific COA correspond to the received shipment?
A: Every COA carries the same lot number printed on the product label and outer packaging. The document references the exact analytical results for that production batch, and retained samples are stored on file for future cross-reference if the receiving laboratory needs to conduct a parallel verification.

Q: What support is available if the buyer’s QC re-test result differs from the supplied COA?
A: The analytical method summary provides full chromatographic parameters so your lab can replicate the original separation. If a discrepancy persists, retained samples from the same lot can be re-tested in parallel, and technical support is available to compare conditions and identify the source of variation.

Q: What are the recommended storage conditions and shelf life for lyophilized Ara290?
A: Lyophilized Ara290 should be stored sealed and light-protected at -20°C, where it maintains specification for 24 months from the manufacturing date. Once reconstituted with sterile water or buffer, aliquoting is recommended to avoid repeated freeze-thaw cycles that can promote aggregation.

Q: What documentation is included with each order and can additional spectra be requested?
A: Each shipment includes a batch-specific COA, HPLC and MS spectra, analytical method summary, safety data sheet, storage and handling sheet, and cold-chain transit record. Additional spectra or method details can be provided upon request by referencing the order and lot number.

Need a Quick Quote?

Response within 24 hours. Sample delivery in 3-5 days.

Get Quote Now

Quality Documents

  • Certificate of Analysis
    Per-batch COA available
  • HPLC Report
    Purity ≥ 99% verified
  • Mass Spectrometry
    Molecular identity confirmed

All documents provided upon confirmed order. Contact us to request sample reports.

Tags

>99% HPLC Ara290 Batch Traceable Lyophilized Powder Reference Standard Research Peptide Research Use
100KG+
Annual Capacity
99%+
Guaranteed Purity
30+
Countries Served
7-15
Days Delivery
Fast Response Guaranteed

Request a Sample or Quote

Fill in your requirements and our team will respond within 24 hours with pricing, availability, and sample options.

Product Inquiry: Ara290 Peptide Raw Powder >99% HPLC Verified

By submitting, you agree to be contacted by our team. We respect your privacy and never share your information.

Related Products

Explore our other high-purity peptide offerings